TABLE I. Electrical performance characteristics and physical requirements.
Weight
Power
Ambient
Imped-
Frequency
Average
VSWR
Insertion
Amplitude
Isolation
Phase
pounds
level
temperature
M23971
ance
range
coupling
max
loss
balance
min (dB)
balance
(grams)
/11-
(ohms)
(MHz)
(dB)
max (dB)
(dB)
max
Operating
Storage
avg
pk
max
(degree)
(W)
(W)
�2
0�
-65�
01
50
29-31
3. +.5
1.2:1
0.2
25
1/
-
.25
.006
to +65�C
to +71�C
-.0
(2.72)
�2
-45�
-55�
02
50
91.2-
3. +.2
1.2:1
0.2
25
1/
-
.25
.006
to +81�C
to +81�C
100.8
-.0
(2.72)
1/ Amplitude balance: Between output ports, �0.6 dB maximum, at 25�C, �0.7 dB maximum over operating temperature range.