TABLE I. Electrical performance characteristics and physical requirements.
Weight
Power
Ambient
Imped-
Frequency
Average
VSWR
Insertion
Amplitude
Isolation
Phase
pounds
level
temperature
M23971
ance
range
coupling
max
loss
balance
min (dB)
balance
(grams)
/11-
(ohms)
(MHz)
(dB)
max (dB)
(dB)
max
Operating
Storage
avg
pk
max
(degree)
(W)
(W)
±2
0°
-65°
01
50
29-31
3. +.5
1.2:1
0.2
25
1/
-
.25
.006
to +65°C
to +71°C
-.0
(2.72)
±2
-45°
-55°
02
50
91.2-
3. +.2
1.2:1
0.2
25
1/
-
.25
.006
to +81°C
to +81°C
100.8
-.0
(2.72)
1/ Amplitude balance: Between output ports, ±0.6 dB maximum, at 25°C, ±0.7 dB maximum over operating temperature range.