TABLE I. Electrical characteristics - Continued.
Attenuation dB
Maximum power
VSWR 1/
input
Dash
Maximum
Weight
Dimension L
number
(oz)
(inches)
Deviation
AV (W)
Peak
Max
Maximum
Nominal
3/
DC to
4.0 to
8.0 to
12.4 to
at 25°C
DC to
DC to
(kW) 4.0 GHz
8.0 GHz
12.4 GHz
18.0 GHz
18 GHz (continuously)
12.4 GHz
2/
13
N
6
---
5
1.0
1.15:1
1.20:1
1.25:1
---
3
2.70
±0.3
S
(68.58)
T
14
N
10
---
5
1.0
1.15:1
1.20:1
1.25:1
---
3
2.70
±0.4
S
(68.58)
T
15
N
13
---
5
1.0
1.15:1
1.20:1
1.25:1
---
3
2.70
±0.5
S
(68.58)
T
16
N
20
---
5
1.0
1.15:1
1.20:1
1.25:1
---
3
2.70
±0.5
S
(68.58)
T
18
N
40
---
5
1.0
1.15:1
1.20:1
1.25:1
---
5
2.70
±0.8
S
(68.58)
T
19
N
50
---
5
1.0
1.15:1
1.20:1
1.25:1
---
5
2.70
±1.0
S
(68.58)
T
20
N
60
---
5
1.0
1.15:1
1.20:1
1.25:1
---
5
2.70
±1.0
S
(68.58)
T
21
N
3
---
2
0.2
1.12:1
1.15:1
1.18:1
1.20:1
3
2.70
±0.3
S
(68.58)
T
22
N
6
---
2
0.2
1.12:1
1.15:1
1.18:1
1.20:1
3
2.70
±0.3
S
(68.58)
T
23
N
10
---
2
0.2
1.12:1
1.15:1
1.18:1
1.20:1
3
2.70
±0.5
S
(68.58)
T
24
N
20
---
2
0.2
1.12:1
1.15:1
1.18:1
1.20:1
3
2.70
±0.5
S
(68.58)
T
1/
VSWR value is for both ends.
2/
Power input is derated linearly to 0 watts at +125°C.
-4
3/
Peak power for a duty cycle of 5 x 10 ; maximum pulse duration of 5 microseconds.
4/
Canceled and replaced with DLA Land and Maritime drawing 13015-05.