TABLE I. Electrical characteristics.
Coupling (dB)
VSWR max
RF input power to primary
Dash
Frequency
Coupling
Effective
Insertion
number
range
variation
directivity
loss
(MHz)
(dB) max
(dB) min
(dB) max
Nominal
Tolerance
Primary
Secondary
Over frequency
Avg
Peak
line
line
range (watts)
(W)
(KW)
±1.0
±1.0
001N
25 - 35
25
25
0.25
1.20:1
1.20:1
5
5
---
S
±1.0
±0.75
002N
125 - 250
30
15
0.30
1.15:1
1.15:1
50
50
---
S
±1.25
±0.75
003N
125 - 250
10
25
0.20
1.10:1
1.10:1
50
50
3
S
±0.5
±0.5
004N
250 - 500
6
25
0.10
1.10:1
1.25:1
100
100
6
S
±0.75
±0.75
005N
250 - 500
10
25
0.10
1.10:1
1.25:1
100
100
6
S
±1.0
±1.0
006N
250 - 500
20
25
0.10
1.10:1
1.25:1
100
100
5
S
±1.0
±1.0
007N
250 - 500
30
25
0.10
1.10:1
1.25:1
100
100
6
S
±1.0
±1.0
008N
285 - 315
25
25
0.25
1.20:1
1.20:1
5
5
---
S
±1.0
±0.5
009N
20 - 60
15
30
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
010N
68 - 82
30
30
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±1.0
011N
102 - 138
30
25
0.25
1.20:1
1.20:1
5
5
---
S
±1.0
±0.5
012N
2 - 100
10
30
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
013N
2 - 100
15
30
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
014N
2 - 100
20
30
0.5
1.30:1
1.30:1
5
5
---
S
±0.2
015N
270 - 330
20
+0.6
40
0.6
1.30:1
1.30:1
5
5
---
S
-0.0
±0.3
±0.25
016N
420 - 450
16
25
0.35
1.15:1
1.20:1
10
10
---
S
±1.0
±0.5
017N
50 - 500
10
25
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
018N
10 - 500
15
25
0.5
1.20:1
1.30:1
5
5
---
S
±0.25
±0.25
019N
10 - 500
15
25
0.35
1.20:1
1.20:1
10
10
---
S
±1.0
±0.5
020N
50 - 400
10
25
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
021N
100 - 500
20
25
0.5
1.30:1
1.30:1
5
5
---
S
±1.0
±0.5
022N
10 - 1000
20
25
0.6
1.30:1
1.30:1
5
5
---
S
±0.5
±0.5
023N
75 - 1000
10
25
0.6
1.30:1
1.30:1
2
2
---
S
For Parts Inquires submit RFQ to Parts Hangar, Inc.