MIL-DTL-15370/16C
TABLE II. Physical and environmental characteristics.
Dash
Weight
Temperature range
Shock
number
(average)
(operating on top
(specified pulse)
non-operating on
(method 213)
1/
bottom)
(oz)
-54°C to +75°C
H
001
0.9
-62°C to +75°C
-55°C to +85°C
C
002
4.5
-55°C to +85°C
0°C to +50°C
H
003
6.5
-62°C to +75°C
-55°C to +85°C
N/A
004
5.0
-55°C to +85°C
-55°C to +85°C
005
5.0
N/A
-55°C to +85°C
-55°C to +85°C
N/A
006
5.0
-55°C to +85°C
-55°C to +85°C
N/A
007
5.0
-55°C to +85°C
-54°C to +75°C
H
008
0.9
-62°C to +75°C
-55°C to +105°C
H
009
1.5
-55°C to +125°C
-55°C to +105°C
H
010
1.5
-55°C to +105°C
-55°C to +105°C
H
011
1.5
-55°C to +125°C
-55°C to +105°C
H
012
1.5
-55°C to +125°C
-55°C to +105°C
H
013
1.5
-55°C to +125°C
-55°C to +105°C
H
014
1.5
-55°C to +125°C
-55°C to +105°C
H
015
1.5
-55°C to +125°C
-54°C to +100°C
H
016
1.5
-55°C to +125°C
-55°C to +105°C
H
017
1.5
-55°C to +125°C
-55°C to +105°C
H
018
1.5
-55°C to +125°C
-54°C to +100°C
H
019
1.5
-55°C to +125°C
-55°C to +105°C
H
020
1.5
-55°C to +125°C
-55°C to +105°C
H
021
1.5
-55°C to +100°C
-55°C to +105°C
H
022
1.5
-55°C to +125°C
-55°C to +100°C
H
023
1.5
-55°C to +125°C
1/ Letters denote test conditions of MIL-STD-202.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business