TABLE I. Electrical performance characteristics and physical requirements.
Amplitude
Power level
Weight
Ambient temperature
Figure
M23971/14-
Impedance
Frequency
Average
VSWR
Insertion
Isolation
Phase
(ohms)
range
balance
pounds
coupling
max
loss
min (dB)
balance
avg
pk
(MHz)
max (dB)
(grams)
(dB)
max (dB)
max
(W)
(W)
Operating
Storage
(degree)
01
50
5-100
3.0 + 0.2
1.3:1
0.4
30
±1.0
± 0.1
---
1.0
.006
-20°C
-40°C
1
-0.0
(2.8)
to +71°C
to +85°C
02
50
10-25
3.0 + 0.6
1.3:1
0.6
25
±1.0
± 0.1
---
1.0
.006
-55°C
-65°C
1
-0.0
(2.8)
to +85°C
to +100°C
25-500
30
03
50
300-500
3.0 + 0.2
1.3:1
0.5
30
±2.0
± 0.1
---
1.0
.006
-20°C
-40°C
1
-0.0
(2.8)
to +71°C
to +85°C
04
50
3-32
4.8 + 0.3
1.2:1
0.6
30
±2.0
± 0.2
---
0.5
.008
-20°C
-40°C
2
-0.0
(3.5)
to +71°C
to +85°C
10-25
---
1.5:1
---
05
50
25-500
---
1.35:1
---
25
±2.0
±0. 2
---
1.0
.006
-55°C
-55°C
3
10-400
6.0 + 0.75
---
0.75
(2.8)
to +85°C
to +85°C
-0.0
400-500
6.0 + 0.85
---
0.85
-0.0
AMSC N/A
FSC 5985
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business