TABLE II. Electrical performance characteristics and physical requirements - Continued.
Weight
Figure
M23971/16-
Impedance
Frequency
Average
VSWR
Insertion
Isolation
Phase
Amplitude
Power level
Ambient temperature
pounds
(ohms)
range
coupling
max
loss
min (dB)
balance
balance
avg
pk
Operating
Storage
(grams)
GHz
(dB)
max (dB)
max
max (dB)
(W)
(W)
(degree)
-54°C
-57°C
250-500
6.0 + 0.5
.062
± 1.0
± 0.2
to +71°C
to +71°C
11
50
MHz
- 0.0
1.3:1
1.0
30
2
---
(28)
5
0°C
0°C
6.0 + 0.5
.37
± 6.0
± 0.6
to +71°C
to +71°C
12
50
1-2
- 0.0
1.35:1
0.6
20
.1
---
(170)
6
0°C
0°C
6.0 + 0.9
.316
.36
± 6.0
± 0.6
to +71°C
to +71°C
13
50
1-2
- 0.0
1.35:1
0.6
20
2/
---
(160)
6
-54°C
-57°C
6.0 + 0.5
.360
± 3.0
± 0.3
to +71°C
to +71°C
14
50
2-4
- 0.0
1.35:1
0.6
18
.1
---
(162)
6
-46°C
-57°C
10-100
7.8 + 0.7
.19
± 2.0
± 0.2
to +63°C
to +7°C
15
50
MHz
- 0.0
1.3:1
1.0
30
2
---
(160)
7
1/ Power level: 275 watt, peak, minimum for 100 nanoseconds.
2/ Power level: When used as a power combiner, the maximum power to each port is .0794 watts for coherent (equal amplitude, phase, and frequency)
signals. For 180° out of phase signals power rating is reduced to .02 watts per port.