MIL-DTL-83739D
3.5.11 Frequency range. Switches shall be designed to operate throughout specified frequency range (see 3.1).
3.5.12 Electromagnetic interference. Electromagnetic interference requirements for switches shall be in
accordance with MIL-STD-461.
3.6 Performance.
3.6.1 Switching rate. When switches are tested as specified in 4.7.2, the switching rate shall not exceed the value
specified (see 3.1).
3.6.2 Primary input power. When switches are tested as specified in 4.7.2, the primary input power shall not
exceed the value specified (see 3.1).
3.6.3 Transition (overlap) time. When switches are tested as specified in 4.7.3, the transition time shall not exceed
the value specified (see 3.1). The transition time is the period when the outputs are considered in parallel and the
isolation is minimum.
3.6.4 Voltage standing wave ratio (VSWR). When switches are tested as specified in 4.7.4, the VSWR shall not
exceed the value(s) specified (see 3.1).
3.6.5 Isolation. When switches are tested as specified in 4.7.5, the isolation between outputs shall be not less
than the value specified (see 3.1).
3.6.6 Insertion loss. When switches are tested as specified in 4.7.6, the insertion loss shall not exceed the value
specified (see 3.1).
3.6.7 RF power handling capability. When switches are tested as specified in 4.7.7, with rated peak power, and
rated average power (when specified, see 3.1) passing through the switch, no evidence of breakdown shall be
evident. Following each test, the VSWR value (see 3.1) shall be no greater than specified (see 3.1). Unless
otherwise specified (see 3.1), switches shall be required to switch under power.
3.6.8 Temperature shock. When switches are tested as specified in 4.7.8, the VSWR, isolation, insertion loss,
primary input power, switching rate, and transition time shall be as specified (see 3.1).
3.6.9 Vibration. When switches are tested as specified in 4.7.9, the VSWR, isolation, insertion loss, primary input
power, switching rate, and transition time shall be as specified (see 3.1).
3.6.10 Humidity (applicable to type E only). When switches are tested as specified in 4.7.10, the VSWR, isolation,
insertion loss, primary input power, switching rate, and transition time shall be as specified (see 3.1).
3.6.11 Hermetic seal (applicable to type H only). When switches are tested as specified in 4.7.11, the leakage rate
shall not exceed the applicable value specified below. The volume shall be computed using the external dimensions
of the switch housing, disregarding any mounting (screw, stud).
Sealed volume of case
Maximum allowable leakage
-6
Greater than 2 cubic inches
1 x 10 atm cc/sec
-8
2 cubic inches or less
1 x 10 atm cc/sec
3.6.12 Immersion (applicable to type I only). When switches are tested as specified in 4.7.12, the VSWR,
isolation, insertion loss, primary input power, switching rate, and transition time shall be as specified (see 3.1).
3.6.13 Salt Atmosphere . When switches are tested as specified in 4.7.13, the VSWR, isolation, insertion loss,
primary input power, switching rate, and transition time shall be as specified (see 3.1).
3.6.14 Shock. When switches are tested as specified in 4.7.14, the VSWR, isolation, insertion loss, primary input
power, switching rate, and transition time shall be as specified (see 3.1).