MIL-DTL-83739D
TABLE III. Group A inspection.
Requirement
Test
Examination or test
paragraph
paragraph
Subgroup I
Visual and mechanical examination - - - - - - - - - - - - - - - - - - - - - - - -
Marking - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.7
4.7.1
Switching rate- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.1
Primary input power - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.2
Transition time - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.3
Voltage standing wave ratio- - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.4
Isolation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.5
Insertion loss- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
3.6.6
Subgroup II
Acceptance reliability- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
---
4.6.1.2.1 Group A sampling plan. For subgroup II, the monthly sample size shall be tested. Statistical sampling
and inspection shall be performed on an inspection lot basis with a random sample of switches selected in
accordance with table IV. Acceptance shall be based upon the zero defect sampling plan. No failures shall be
permitted.
TABLE IV. Group A sampling plan.
Lot size
Sample size
1 - 13
100 percent
14 - 150
13
151 - 280
20
281 - 500
29
501 - 1,200
34
1,201 - 3,200
42
3,201 - 10,000
50
10,001 - 35,000
60
35,001 - 150,000
74
150,001 - 500,000
90
500,001 and over
102
4.6.1.3 Rejected lots. If an inspection lot is rejected, the supplier may rework it to correct the defects, or screen
out the defective units, and resubmit for inspection. Such lots shall be separated from new lots, and shall be clearly
identified as re-inspected lots.
4.6.2 Conformance verification inspection. Conformance verification inspection shall consist of group B. Delivery
of products which have passed group A shall not be delayed pending the results of these conformance verification
inspections.
4.6.2.1 Group B inspection. Group B inspection shall consist of the tests specified in table V in the order shown.
Group B inspection shall be made on sample units which have passed group A inspection.