MIL-DTL-15370J
TABLE III. Group A inspection.
Examination or test
Requirement paragraph
Test paragraph
Visual and mechanical examination - - - - - -
3.4.15, 3.4.16,
3.21, and 3.22
Coupling - - - - - - - - - - - - - - - - - - - - - - - - -
Coupling variation - - - - - - - - - - - - - - - - - - -
3.5.2
3.5.5.1
VSWR of primary line - - - - - - - - - - - - - - - 1/
VSWR of secondary line - - - - - - - - - - - - - -1/
Insertion loss - - - - - - - - - - - - - - - - - - - - - -1/
4.6.1.2.1 Sampling plan. The group A sampling plan for accept on zero defects shall be as specified in table IV.
TABLE IV. Group A Sampling plan.
Lot size
Sample size
2
to
12
100 % of lot
13
to
150
13
151
to
280
20
281
to
500
29
501
to
1200
34
4.6.1.2.2 Rejected lots. If an inspection lot is rejected, the supplier may rework it to correct the defects, or screen
out the defective units, and resubmit for re-inspection. Resubmitted lots shall have all devices re-inspected. Such
lots shall be separated from new lots, and shall be clearly identified as re-inspected lots. Resubmitted lots indicating
device failures shall constitute a rejected lot.
4.6.1.3 Group B inspection. Group B, when specified (see 6.2.k), inspection shall consist of the tests specified in
table V and the sample shall be selected from inspection lots that have passed the group A inspection. The acquiring
activity may accept a certificate of compliance (see 4.6.1.3.4) in lieu of group B inspection.
13