TABLE I. Electrical performance characteristics and physical requirements.
Imped-
Frequency
Averag
VSWR
Insertion
Isolation
Phase
Amplitude
Power
Weight
Ambient
M23971
ance
range
e
max
loss
min (dB)
balance
balance
level
pounds
temperature
Figure
/5-
max (dB)
max
(dB)
(grams)
(ohms)
(MHz)
couplin
avg
pk
Operating
Storage
(degree)
max
g
(W)
(W)
(dB)
±1.0
±0.1
-35°
-40°
01
50
5-25
3. +.2,
1.3:1
0.3
25
0.5
1.0
.006
1
to +105°C
to +125°C
-.0
(2.83)
±2.0
±0.2
-55°
-55°
02
50
0.2-200
4.8 +.5
1.3:1
0.5
25
0.5
.5
.006
2
to +125°C
to +125°C
-0.0
(2.83)
±1.0
±0.1
-55°
-55°
03
50
10-500
3. +.2
1.3:1
0.5
30
1.0
N/A
.006
1
to +85°C
to +85°C
-0.0
(2.83)