MIL-DTL-15370/9H
TABLE II. Electrical requirements.
Dash
Frequency
Coupling (dB)
Coupling
Effective
Insertion
VSWR max
RF Input power to primary
Reflected
Number
range
variation
directivity
loss
avg
Nominal
Tolerance
Primary
Secondary
Over
Avg
Peak
power
(dB) max
(dB)
(dB) max
line
line
frequency
(max)
range
GHz
Watts
Watts
KW
Watts
±1.0
±0.6
001
1-2
6
25
0.2
1.15:1
1.15:1
50
50
3
2
±1.2
±0.75
002
1-2
10
25
0.2
1.10:1
1.10:1
50
50
3
5
±1.2
±0.75
003
1-2
20
27
0.2
1.10:1
1.10:1
50
50
3
50
±1.2
±0.75
004
1-2
30
27
0.2
1.10:1
1.10:1
50
50
3
50
±1.0
±0.6
005
2-4
6
22
0.2
1.15:1
1.15:1
50
50
3
2
±1.2
±0.75
006
2-4
10
22
0.2
1.15:1
1.15:1
50
50
3
5
±1.2
±0.75
007
2-4
20
22
0.2
1.15:1
1.15:1
50
50
3
50
±1.2
±0.75
008
2-4
30
22
0.2
1.15:1
1.15:1
50
50
3
50
±1.0
±0.6
009
4-8
6
18
0.25
1.25:1
1.25:1
50
50
3
2
±1.2
±0.75
010
4-8
10
20
0.25
1.25:1
1.25:1
50
50
3
5
±1.2
±0.75
011
4-8
20
20
0.25
1.25:1
1.25:1
50
50
3
50
±1.0
±0.5
012
7-12.4
6
15
0.4
1.30:1
1.30:1
50
50
3
2
±1.0
±0.5
013
7-12.4
10
17
0.4
1.30:1
1.30:1
50
50
3
5
±1.0
±0.5
014
7-12.4
20
17
0.3
1.25:1
1.25:1
50
50
3
50
±1.0
±0.5
015
12.4-18
6
15
0.3
1.35:1
1.40:1
50
50
3
2
±1.0
±0.5
016
12.4-18
10
15
0.3
1.30:1
1.40:1
50
50
3
5
±1.0
±0.5
017
12.4-18
20
15
0.5
1.35:1
1.40:1
50
50
3
50
±1.0
±0.5
018
7-12.4
30
17
0.3
1.25:1
1.25:1
50
50
3
50
±1.0
±0.5
019
11-17
10
15
0.3
1.30:1
1.30:1
5
5
5
5
See footnotes at end of table.
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business