MIL-DTL-15370/9H
TABLE II. Electrical requirements - Continued.
Dash
Frequency
Coupling (dB)
Coupling
Effective
Insertion
VSWR max
RF Input power to primary
Reflected
Number
range
variation
directivity
loss
avg
Nominal
Tolerance
Primary
Secondary
Over
Avg
Peak
(dB)
power
(dB) max
(dB)
line
line
frequency
max
(max)
range
GHz
Watts
Watts
KW
Watts
±1.0
±0.5
020
11-17
20
20
0.5
1.30:1
1.30:1
40
40
5
40
±1.0
±0.5
021
11-17
30
20
0.5
1.30:1
1.30:1
40
40
5
40
±1.1
±0.6
022
7.5-16
6
12
0.6
1.35:1
1.45:1
50
50
2
2
±1.5
±0.75
023
7.5-16
10
12
0.6
1.35:1
1.45:1
50
50
2
5
±1.25
±0.75
024
7.5-16
20
15
0.5
1.35:1
1.45:1
50
50
2
50
±1.25
±0.75
025
7.5-16
30
15
0.5
1.35:1
1.45:1
50
50
2
50
±1.0
±0.5
026
1-18
16
1.0-12.4 GHz:
0.8
1.40:1
1.50:1
20
20
3
5
15
12.4-18.0 GHz
12
±1.0
±0.75
1/
1-2
10
25
0.2
1.15:1
1.15:1
50
50
4
10
027
±1.0
±0.75
2/
1-2
30
25
0.2
1.15:1
1.15:1
50
50
4
50
028
±1.2
±0.75
3/
1-2
10
25
0.2
1.10:1
1.10:1
50
50
3
5
029
±1.2
±0.75
3/
1-2
20
27
0.2
1.10:1
1.10:1
50
50
3
50
030
±1.2
±0.75
3/
1-2
30
27
0.2
1.10:1
1.10:1
50
50
3
50
031
±1.2
±0.75
4/
2-4
20
20
0.2
1.25:1
1.25:1
50
50
10
5
032
±1.2
±0.75
5/
4-8
10
18
0.25
1.25:1
1.25:1
5
5
7.5
2
033
±1.2
±0.75
5/
4-8
30
20
0.25
1.20:1
1.20:1
50
50
7.5
50
034
±1.0
±0.3
035
2-6
10
17
1.0
1.30:1
1.30:1
50
50
3
5
±1.0
±0.4
036
2-8
6
20
0.5
1.30:1
1.30:1
50
50
3
2
±0.75
±0.5
037
2-8
10
15
1.2
1.50:1
1.50:1
50
50
3
5
See footnotes at end of table.
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business