MIL-DTL-3928/15G
1/ M3928/15-06 has been deleted.
2/ At nominal V dc and 20 deg C.
3/ Enclosure shall be explosion proof.
4/ Transient interface (RFI).
5/ The VSWR from dc to 7 GHz is 1.25:1 maximum.
6/ The insertion loss from dc to 7 GHz is 0.3 dB maximum.
7/ Switch must return to de-energized position at no less than 2 volts.
8/ Make before break sequence.
9/ Pulse operation: Switch shall change from open to closed position when +4 V dc min is applied Switch shall
change from closed to open when voltage falls below +1.5 V dc.
10/ Logic voltage: Logic 0 - 0 to 0.4 V dc and Logic 1 - 2.4 to 5.5 V dc.
11/ +5 voltage deviation: ±0.5 V dc.
12/ VSWR max for 1 to 4 GHz is 1.4:1, for dc to 1 GHz is 1.3:1.
13/ Insertion loss max for 1 to 4 GHz is 0.4 dB, for dc to 1 GHz is 0.3 dB.
14/ VSWR max for 8 to 12 GHz is 1.4:1, 4 to 8 GHz is 1.3:1, 1 to 4 GHz is 1.2:1, dc to 1 GHz is 1.1:1.
15/ Insertion loss max for 8 to 12 GHz is 0.4 dB, 4 to 8 GHz is 0.3 dB, 1 to 4 GHz is 0.2 dB, dc to 1 GHz is 0.1 dB.
16/ Isolation min for 8 to 12 GHz is 80 dB, 1 to 8 GHz is 90 dB, dc to 1 GHz is 95 dB.
17/ VSWR max for 8 to 12.4 GHz is 1.4:1, 4 to 8 GHz is 1.25:1, dc to 4 GHz is 1.2:1.
18/ Insertion loss max for 8 to 12.4 GHz is 0.4 dB, 4 to 8 GHz is 0.3 dB, dc to 4 GHz is 0.2 dB.
19/ Isolation min for 8 to 12.4 GHz is 65 dB, 4 to 8 GHz is 70 dB, dc to 4 GHz is 75 dB.
TABLE I. Electrical and performance characteristics - Continued.
33