MIL-PRF-49204B(CR)
TABLE IV.
Sampling plan for Group B inspection.
Lot Size
Sample Size
3
2 to 25
5
26 to 50
6
51 to 90
7
91 to 150
10
151 to 280
11
281 to 500
15
501 to 1200
18
1201 to 3200
22
3201 to 10,000
29
10,001 and over
NOTE:
The Acceptance Number in all cased is ZERO.
TABLE V. Group B Sampling Plan.
(for Interchangeability inspection only)
Lot Size
Sample Size
2
2
to 15
3
16
to 25
5
26
to 50
5
51
to 90
6
91
to 150
7
151
to 280
9
281
to 500
11
501
to 1200
13
1201
to 3200
15
3201
and over
NOTE:
The Acceptance Number in all cases is ZERO.
4.5.2 Procedure in the event of failure during Group B inspection. In
the event of failure to pass any Group B inspection item, the unit shall be
corrected as necessary and then resubmitted to Group B inspection. After
successful retest, the same correction shall be applied to all other uncovered
systems on order.
4.6 Group C inspection. This inspection shall be as specified in Table
VI and shall be performed on units that met Group A and Group B inspection.