MIL-DTL-24044C
3.6 Insertion force. When measured as specified in 4.6.3, the insertion force of the inner connector into the inner
conductor of the line shall be as specified.
Line size
Force (pounds)
7/8
7 to 18
1-5/8
10 to 20
3-1/8
10 to 20
6-1/8
25 to 40
3.7 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally
preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the
operational and maintenance requirements, and promotes economically advantageous life cycle costs. All
components supplied shall be new and unused.
3.8 High potential. The flanges and insulator bullet assemblies shall show no evidence of voltage breakdown
when tested as specified in 4.6.5.
3.9 Marking. Flanges shall be marked in accordance with MIL-STD-130, with the part number and the
manufacturer s code symbol. Marking shall be in depressed or raised characters approximately .094-inch high, in the
location specified (see 3.1).
3.10 Workmanship. Flanges shall be processed in such a manner as to be uniform in quality, and all surfaces
shall be free of burrs, die marks, chatter marks, scratches, dirt, grease, scale, splinters and other defects that will
affect life, serviceability, or appearance.
4. VERIFICATION
4.1 Test equipment and inspection facilities. The test equipment and inspection facilities shall be of sufficient
accuracy, quality, and quantity to permit performance of the required inspection. The supplier shall establish
calibration of inspection equipment to the satisfaction of the Government.
4.2 Classification of inspection. The examination and testing of flanges shall be classified as follows:
Materials inspection (see 4.3).
a.
b.
Conformance inspection (see 4.5).
(1)
Inspection of product for delivery (see 4.5.1).
4.3 Materials inspection. Materials inspection shall consist of verification that the materials listed in table I, used in
fabricating the flanges, are in accordance with the applicable referenced specifications or requirements prior to such
fabrication. Except for Navy acquisitions, a certificate of analysis furnished by the supplier may constitute verification.