MIL-DTL-24044C
4.5.1.3.1 Sampling plan. This specification utilizes an accept on zero defect (c = 0) sampling plan. Statistical
sampling and inspection shall be performed on an inspection lot basis with a random sample of flanges selected in
accordance with table III. No failures shall be permitted.
TABLE III. Group A sampling plan.
Lot size
Sample size
1 - 13
100 percent
14-150
13
151-280
20
281-500
29
501-1200
34
1201-3200
42
3201-10,000
50
10,001-35,000
60
35,001-150,000
74
150,001-500,000
90
500,001 and over
102
4.5.1.3.2 Disposition of sample units. Sample units which have passed the group A inspection may be delivered
on the contract or order if the lot is acceptable.
4.5.1.4 Group B inspection. Group B inspection shall consist of the test specified in table IV.
4.5.1.4.1 Sampling plan. The sampling plan shall be in accordance with table III for sample inspection. Unless
otherwise specified herein, inspection shall be used. Acceptance shall be based upon the zero defect sampling plan
in table III.
4.5.1.4.2 Disposition of sample units. Sample units which have passed the group B inspection may be delivered
on the contract or order if the lot is acceptable.
TABLE IV. Group B Inspection.
Examination
Requirement
Method
or test
paragraph
paragraph
Insertion force
4.5.1.5 Group C inspection. Group C inspection shall consist of the tests specified in table V.
4.5.1.5.1 Sampling plan. Four sample units of each type on order shall be selected from the first quantities
produced. Thereafter, four samples of each type from every 500 or fraction thereof produced, or four samples of
each type from each month s production, whichever occurs first.
4.5.1.5.2 Disposition of sample units. Sample units which have passed the group C inspection may be delivered
on the contract or order if the lot is acceptable.
6
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business