MIL-DTL-39030F
a. Special preparation The terminal shall not have been soldered previously.
b. Depth of insertion in the molten solder To a point 0.062 inch (1.57mm) + 0.031 (0.79mm), -0 inch
(0.0 mm) from the body.
c. Test condition A.
d. Cooling time - stabilize to +25°C.
4.6.7 Resistance to solvents (see 3.10). Dummy loads shall be tested in accordance with method 215
of MIL-STD-202. The following details shall apply:
All portions of the dummy loads shall be brushed. Optional procedures for a fourth group are not
applicable.
4.6.8 Terminal strength (see 3.11). Dummy loads shall be tested in accordance with method 211
of MIL-STD-202 test condition A, applied force1.5 pounds.
4.6.9 Burn-in (screened only)(see 3.12). All screened dummy loads shall be subjected to the specified
rated average power (see 3.1), at the highest specified operating temperature (see 3.1) for a period of 96
+5,-0 hours. Where applicable (see 3.1), the dummy loads may be mounted to a heat sink. After the
burn-in, the VSWR of the dummy load shall be measured and the measured value shall be no greater
than the value specified (see 3.1). If the VSWR value exceeds that specified, the dummy loads shall be
considered to have failed. All dummy loads subjected to burn-in shall be serialized (see 3.24.1) for
correlation of the VSWR data to the specific unit.
sweep frequency technique or at 10 equally spaced points evenly distributed across the frequency range
using a slotted line method. The test equipment(s) shall be capable of providing a continuous
measurement of VSWR over the specific frequency range. A means shall be provided for producing a
permanent record of the dummy load's VSWR versus frequency. If VSWR is not directly measured; that
is, if return loss is measured and VSWR is calculated from that measurement, the permanent record shall
indicate the worse case VSWR numerically for each frequency band and shall provide the calculation
used to obtain the calculated value. The permanent record of each dummy load shall be packaged with
the unit when shipped. The measurement system and permanent record shall provide a minimum
accuracy of .01 over the frequency ranges below 26.5 GHz and a minimum accuracy of .02 over the
frequency ranges 26.5 GHz and above.
4.6.11 Thermal shock (see 3.14). With the RF connection uncovered, dummy loads shall be tested in
accordance with method 107 of MIL-STD-202. The following details shall apply:
a. Test condition B, unless otherwise specified (see 3.1).
b. Final measurement VSWR shall be measured as specified in 4.6.10.
specified in 4.6.12.1. When specified (see 3.1), dummy loads shall be tested as specified in 4.6.12.2.
4.6.12.1 Simple harmonic nature. Dummy loads shall be tested in accordance with method 201 of
MIL-STD-202. The following details shall apply:
a. Tests and measurements prior to vibration None.
b. Method of mounting Rigidly mounted to the test platform by its normal mounting means. Dummy
loads which employ rubber bumpers as isolators shall have these isolators removed and the
dummy loads in turn held secure to the test platform during the test. Small dummy loads not
14