3.16 Shock. After the shock test specified in 4.6.13, the dummy load shall show no physical damage,
and the VSWR shall not exceed the value specified (see 3.1).
3.17 Moisture resistance. After the moisture resistance test specified in 4.6.14, the dummy load shall
show no physical damage, and the VSWR shall not exceed the value specified (see 3.1).
3.18 Barometric pressure (when specified). After the barometric pressure test specified in 4.6.15, the
dummy load shall show no physical damage, and the VSWR shall not exceed the value specified (see
3.1).
3.19 Salt spray (when specified). After the salt spray test specified in 4.6.16, the dummy load shall
show no physical damage, and the VSWR shall not exceed the value specified (see 3.1).
3.20 Power dissipation. After the power dissipation test specified in 4.6.17, the dummy load shall show
no physical damage, and the VSWR shall not exceed the value specified (see 3.1). For liquid cooled
loads, the outside temperature of the water shall not exceed the value specified (see 3.1).
3.21 Endurance. After the endurance test specified in 4.6.18, the dummy loads shall show no physical
damage, and the VSWR shall not exceed the value specified (see 3.1). For liquid cooled loads, the
outside temperature of the water shall not exceed the value specified (see 3.1).
3.22 Overload (when specified). After the overload test specified in 4.6.19, the dummy load shall show
no physical damage, and the VSWR shall not exceed the value specified (see 3.1).
3.23 Pressurization (when specified). During the pressurization test specified in 4.6.20, there shall be
no evidence of loss of pressure as detected by a continuous stream of escaping air bubbles.
manufacturer's CAGE code. The marking location is optional; when practicable, a location should be
picked that will be least likely to be covered in cable assembly or installation. Marking is required on all
parts manufactured to this specification unless specifically excepted (see 3.1).
3.24.1 Serialization. Screened parts are serialized, see 4.6.9. When the contract requires that dummy
loads be serialized, each dummy load shall be marked with a unique serial number assigned
consecutively within the inspection lot, allowing traceability of the dummy load (see 6.2).
3.25 Workmanship. Dummy loads shall be manufactured and processed in such a manner as to be
uniform in quality, and the shell of the dummy load shall be free from tool marks, burrs, sharp edges,
deep scratches, and other defects that will affect life, serviceability, or appearance.
3.26 Recycled, recovered, or environmentally preferable, or biobased materials. Recycled, recovered,
environmentally preferable, or biobased materials should be used to the maximum extent possible,
provided that the material meets or exceeds the operational and maintenance requirements, and
promotes economically advantageous life cycle costs.
4. VERIFICATION
4.1 Classification of inspection. The inspection requirements specified herein are classified as follows:
a. Qualification inspection (see 4.4).
b. Conformance inspection (see 4.5).
c. Periodic inspection (see 4.5.2.1.1).