MIL-DTL-39030F
3.4.9 Ambient temperature. The ambient temperature shall be as specified (see 3.1).
3.4.10 Coolant pressure (when specified). The coolant pressure shall be as specified (see 3.1).
3.5 Force to engage/disengage (when specified for coaxial dummy loads) (see 4.6.2).
3.5.1 Bayonet and threaded types. When tested as specified in 4.6.2.1, the torque necessary to
completely couple or uncouple the connector of the dummy load shall not exceed that specified (see 3.1).
Also the longitudinal force necessary to initiate the engaging or disengaging cycle shall not exceed that
specified (see 3.1).
3.5.2 Push-on connector types. When tested as specified in 4.6.2.2, the forces necessary to fully
engage or disengage the connector of the dummy load shall not exceed that specified (see 3.1).
3.6 Coupling proof torque (when specified for coaxial dummy loads). When tested as specified in
4.6.3, the coupling mechanism (threaded types) shall not be dislodged, and the connector of the dummy
loads shall meet the requirements of 3.5.1.
3.7 Connector durability (when specified for coaxial dummy loads). After the connector of the dummy
loads is tested as specified in 4.6.4, the connector shall meet the requirements of 3.5.1 and 3.5.2.
3.8 Solderability (as applicable). When dummy loads with solderable connections are tested as
specified in 4.6.5, there shall be no evidence of pinholes or blistering.
3.9 Resistance to soldering heat (as applicable). When dummy loads with solderable connections are
tested as specified in 4.6.6, there shall be no damage to the dummy load or to the terminal insulator the
will cause electrical failure. Chipping of the terminal insulator shall not be cause for failure unless that
chipping extends to the outer periphery. After the test, the VSWR shall not exceed the values specified
(see 3.1).
3.10 Resistance to solvents (as applicable). When dummy loads are tested as specified in 4.6.7, there
shall be no evidence of illegible marking, mechanical damage, or deterioration of material of finishes.
3.11 Terminal strength (as applicable). When tested in accordance with 4.7.8, connectors shall not
crack, nor break, and there shall be no loosening of parts. Connectors shall be in full engagement during
vibration and the coupling device shall not loosen as a result of vibration. Interruptions of electrical
continuity shall not last longer than 10 microseconds.
3.12 Burn-in (screened only). All screened dummy loads shall be burn-in as specified in 4.6.9. After
burn-in, the VSWR shall not exceed the value specified and there shall be no evidence of mechanical
damage.
3.13 Voltage standing wave ratio (VSWR). When dummy loads are tested as specified in 4.6.10, the
VSWR shall not exceed the value specified (see 3.1).
3.14 Thermal shock. After the thermal shock test specified in 4.6.11, the dummy load shall show no
physical damage, and the VSWR shall not exceed the value specified (see 3.1).
3.15 Vibration. After the vibration test specified in 4.6.12, the dummy load shall show no physical
damage, and the VSWR shall not exceed the value specified (see 3.1).