equipped with other mounting provisions shall be considered normally mounted when mated with
the complementary mounting receptacle.
c. Test and measurements after vibration VSWR shall be measured as specified in 4.6.10.
4.6.12.2 Random nature. Dummy loads shall be tested in accordance with method 214 of MIL-STD-
202. The following details shall apply:
a. Method of mounting Rigidly mounted to the test platform by its normal mounting means.
b. Test condition II D and 15 minutes duration, unless otherwise specified.
c. Test and measurements after vibration VSWR shall be measured as specified in 4.6.10.
4.6.13 Shock (see 3.16). Dummy loads shall be tested in accordance with method 213 of MIL-STD-
202. The following details shall apply:
a. Mounting Mounted securely on mounting table to simulate service conditions. Small dummy
loads not equipped with other mounting provisions shall be considered normally mounted when
mated with the complementary mounted receptacles.
b. Test condition letter I.
c. Measurements after test VSWR shall be measured as specified 4.6.10.
4.6.14 Moisture resistance (see 3.17). Dummy loads shall be tested in accordance with method 106 of
MIL-STD-202. The following details shall apply:
a. Loading voltage Not applicable.
b. Final measurement - After drying period, VSWR shall be measured as specified 4.6.10.
4.6.15 Barometric pressure (see 3.18). Dummy loads shall be tested in accordance with method 105
of MIL-STD-202. The following details shall apply:
a.
Method mounting Normal mounting means.
Test condition letter As specified (see 3.1).
b.
c.
Measurement after test VSWR shall be measured as specified in 4.6.10.
d.
Tests during subjection to reduction pressure (see 3.1).
e.
Exposure time prior to measurements (see 3.1).
STD-202. The following details shall apply:
a. Mounting Normal mounting means. Normal mounting means shall include mating to
complementary connectors whose cable entries (backends) are sealed against salt spray
penetration (see 3.1).
b. Test condition letter B, salt solution 5 percent.
c. Measurement after test VSWR shall be measured as specified in 4.6.10.
4.6.17 Power dissipation (see 3.20). The specified peak and average power shall be applied
simultaneously at any frequency within the specified range (see 3.1). When no peak power is specified,
apply 1.5 times the rated average power. Power shall be maintained for a period of 15 minutes after the
dummy load has reached thermal equilibrium. It is considered that thermal equilibrium has been reached
when the temperature of the dummy load has not changed by more than 5°C over a period of 5 minutes.
For pressurized dummy loads, the internal pressure shall be as specified (see 3.1). For liquid cooled
dummy loads, the minimum flow rate and coolant pressure specified (see 3.1) shall be used with the input
temperature specified.
15